Customer Service - NOT ACTIVE - You can leave a message
  • -37%
  • New
Wilo CRONO TWIN DL-E 40/220-11/2 in-line...
Wilo CRONO TWIN DL-E 40/220-11/2 in-line inverter pump 3X400Vdn40

Wilo CRONO TWIN DL-E 40/220-11/2 in-line inverter pump 3X400Vdn40

2153806
Last items in stock
€22,891.21 €36,335.26 -37%
Tax included

Description

Construction type

Electronically regulated ventilated motor double pump with inline construction, flange connection and automatic performance adaptation

Application

Pumping of heating water (according to VDI 2035), cold water and abrasive-free water/glycol mixtures in heating, air conditioning and refrigeration systems.

Equipment/Operation

Modes of operation

         ·Δp-c for constant differential pressure

         ·Δp-v for variable differential pressure

         ·PID Control

         ·Operation as a servo motor (n = constant)

Command Level

         ·Green button and display

Manual functions

         ·Setting the differential pressure delivery value

         ·Speed setting (manual selection mode)

         ·Setting the Operating Mode

         ·Pump on/off setting

         ·Configuration of all operating parameters

         ·Confirm errors

External control functions

         ·Control input "Priority Off"

         ·Control input "external pump exchange" (only effective with double pump operation)

         ·Analog input 0–10 V, 0–20 mA for servo motor operation (DDC) and remote control of the delivery value

         ·2–10 V, 4–20 mA analog input for servo motor operation (DDC) and remote control of the delivery value

         ·0–10 V analog input for pressure sensor true value signal

         ·2–10 V, 0–20 mA, 4–20 mA analog input for pressure sensor true value signal

Signaling and display functions

         ·SSM Cumulative Block Signaling

         ·Cumulative SBM Operation Signaling

Data exchange

         ·Infrared communication port for wireless data exchange with IR monitor/IR stick

         ·Plug-in compartment for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to the building automation system

Safety features

         ·Integral motor protection with integrated trip electronics

         ·Access Lock

Double pump management (double pump or 2 single pumps)

         ·Main/backup operation (automatic pump exchange for block)

         ·Main/backup operation pump exchange after 24 hours

         ·Pump addition function

         ·Parallel operation (addition/deactivation, optimized peak load at best performance)

Key to reading

Example

DL-E 50/170-7,5/2-R1

DL-E

Double inline pump with electronic control

50

Nominal diameter DN of the mouth

170

Nominal impeller diameter

7,5

Rated power of the P2 engine in kW

2

Number of poles

R1

Version without pressure sensor

Technical data

         ·Permissible temperature range from -20 °C to +140 °C

         ·Mains power supply

or    3~440 V ±10%, 50/60 Hz

or    3~400 V ±10 %, 50/60 Hz

or    3~380 V -5 % +10 %, 50/60 Hz

         ·Compliance with electromagnetic compatibility without additional measures:

or    Electromagnetic interference emission for residential environments according to EN 61800-3:2018

or    Interference immunity for industrial environments according to EN 61800-3:2018

         ·IP55 rating

         ·Nominal diameter from DN 40 to DN 200

         ·Max. operating pressure 16 bar up to +120 °C, 13 bar up to +140 °C

Materials

         ·Pump body and lantern: EN-GJL-250

         ·Impeller:

or    Standard Version: EN-GJL-200

or    Special version: CuSn 10 bronze

         ·Tree: 1.4122

         ·Mechanical seal: AQEGG; other mechanical seals on request

Construction

Single-stage double pump with low head in inline version with

         ·Changeover valve

         ·Mechanical seal

         ·Flange connection

         ·Lantern

         ·Joint

         ·Engine with integrated electronic speed control

Supply

         ·Pump

         ·Assembly, use and maintenance instructions

Options

         ·Variant ...-R1 without differential pressure transducer

         ·Variant ...-L1 with bronze impeller (for an extra charge)

Fixings

         ·3 shelves with fixing material for base mounting

         ·Blind flanges for double pump casing

         ·IR Monitor, IR Pen

         ·PLR IF module for connection to PLR/communication port converter

         ·LON IF module for connection to the LONWORKS network

         ·BACnet IF Form

         ·Modbus IF module

         ·IF CAN module

         ·VR-HVAC control system

         ·CCe-HVAC control system

         ·SCe-HVAC control system

         ·Pressure Difference Transducer (DDG)

 

Product Details

New

Attachments

Team of experts at your service

Personalized customer support

Choose from millions of products

New offers every day

Free shipping

for orders over €250

Best price guaranteed

Compared to the most renowned websites

ISCRIVITI ALLA NOSTRA
NEWSLETTER

Vuoi ricevere novità e offerte in anteprima?

Product added to wishlist
Product added to compare.